Chapters Transcript Blinking yellow notifications on Kangaroo OMNI™ To continue the feeding regimen that was in process press continue feed to begin a new feeding regimen. Press restart feed pump in active alarm. A pump inactive screen will appear when the pump has not been actively running for more than 10 minutes to resolve the alarm press continue. This will take you to the previous screen. Low battery alarm. A low battery screen will appear when less than 30 minutes of battery life remains to resolve the alarm plug the pump into an electrical outlet. The Kangaroo Omni Enteral feeding pump will continue to return to the screen that was active prior to the error and will continue to operate normally if this alarm occurs while the Kangaroo Omni Enteral feeding pump is plugged in ensure the power adapter plug is completely inserted into the power adapter port on the back of the pump and that the green power led on the front of the pump is illuminated. Feed error alarm. A feed error screen will appear when the feed bag is empty or there is a clog or a kink in the tubing between the feed bag and the pump to resolve the alarm. First check to see if the feed bag is empty. If the feed bag is empty, refill the bag as needed. Press continue prime the pump for next feeding, the patient must not be connected to the pump when priming occurs. If the feed bag contains enteral fluids, resolve the alarm by first check the tubing between the feed bag and the pump to locate the blockage and clear it if possible. Third, restart feeding flushing if the alarm continues. First, ensure the pump is unplugged from an electrical outlet. Second, remove the cassette. Third, clean and dry the occlusion sensor region. Fourth reload the cassette. Fifth press skip prime sixth press start to restart feeding flush air alarm. A flush error screen will appear when the flush bag is empty or there is a clog or kink in the tubing between the flush bag and the pump to resolve the alarm. First check to see if the flush bag is empty. If the flush bag is empty, first refill the bag as needed. Second press continue. Third, prime the pump for next flush. The patient must not be connected to the pump when priming occurs. If the alarm continues. First, ensure the pump is unplugged from an electrical outlet. Second, remove the cassette. Third, clean and dry the occlusion sensor region. Fourth reload the cassette. Fifth press skip prime sixth press start to restart feeding flushing rotor stuck alarm. A rotor stuck screen will appear when the kangaroo omni enteral feeding pump detects excessive resistance on the rotor. Typically caused by enteral fluids or contaminant. Build up to resolve the alarm. Ensure the pump is unplugged from an electrical outlet, clean the rotor with a wet cloth. If alarm continues, press power off and use a different kangaroo omni feeding pump patient two blocked alarm. A patient tube blocked screen will appear when enteral fluids are no longer being delivered because of a clog in the tubing between the kangaroo on the enteral feeding pump and the patient to resolve the alarm. First check tubing between the pump and the patient to locate the blockage. Second, if possible clear the blockage. Third, once cleared press continue. Fourth, restart feeding if the alarm continues, remove cassette from the pump first, ensure the pump is unplugged from an electrical outlet. Second, clean and dry the occlusion sensor region. Third reload cassette. Fourth press continue. Fifth, restart feeding if the alarm continues, replace the feeding set. If the alarm continues after replacing the feeding set, press power off and use a different kangaroo omni and feeding pump cassette dislodged alarm. A cassette dislodge screen will appear when cassette is not properly loaded in the kangaroo omni enteral feeding pump to resolve the alarm reload cassette. If the alarm continues, replace the feeding set. If the alarm continues after replacing the feeding set, press power off and use a different kangaroo omni enter feeding pump cassette error alarm. A cassette error screen will appear when the kangaroo omni enteral feeding pump has detected an unusual operating condition to resolve the alarm. First, remove cassette, second, inspect cassette for irregularities. Third, correct irregularities. Fourth reload cassette be if the alarm continues replace the feeding set. If the alarm continues after replacing the feeding set, press power off and use a different kangaroo omni and feeding pump. Valve error alarm. A valve error screen will appear when the kangaroo omni enteral feeding pump detects an unusual amount of resistance on the valve actuator or the valve actuator is not oriented correctly to resolve the alarm. First, unplug the pump from the electrical outlet. Second, remove cassette, third check valve actuator for blockages. Fourth confirm valve actuator is correctly oriented. Fifth, clean and dry valve actuator, sixth reload cassette if the alarm continues, replace the feeding set. If the alarm continues after replacing the feeding set, press power off and use a different kangaroo omni enteral feeding pump sensor error, one alarm, a sensor error, one screen will appear when the kangaroo on the enteral feeding pump detects an issue with the occlusion detection sensor to resolve the alarm. First, unplug the pump from the electrical outlet. Second, remove cassette. Third check tubing inside cassette for lint or debris. Fourth, clean and dry the occlusion sensor region. Fifth reload cassette. Sixth press continue. Seventh, restart feeding if the alarm continues, replace the feeding set. If the alarm continues after replacing the feeding set, press power off and use a different kangaroo omni enteral feeding pump sensor error two or three alarm. A sensor error two or three screen will appear when the kangaroo Omni enteral feeding pump detects an issue with the force sensor to resolve the alarm. First, unplug the pump from the electrical outlet. Second, remove cassette, third, clean and dry the occlusion sensor region. Fourth reload cassette, fifth press continue, sixth, restart feeding if the alarm continues, replace the feeding set. If the alarm continues after replacing the feeding set, press power off and use a different kangaroo omni and feeding pump. For more information, please refer to the kangaroo omni enteral feeding pump instructions for use. Created by